© 2021 Nordson Corporation
8-16
50-lb Feed Hopper Fluidizing Plate Replacement
1. Empty the hopper and vacuum as much powder as possible out of the hopper.
2. See Figure 8-13. Remove the screws (5) securing the body (1) to the plenum (3). Lift
the body off the plenum.
3.
Remove and discard the old fluidizing plate (2).
4.
Vacuum the inside of the plenum and clean the body and plenum flanges.
5.
Check the O-ring gaskets (4) on the body and plenum flanges and make sure they are
securely installed in the flange grooves.
NOTE:
Make sure the smooth side of the new fluidizing plate is facing up.
6.
Re-assemble the body, fluidizing plate, and plenum with the nylon screws.
CAUTION:
Do not overtighten the nylon screws. Overtightening the screws will result in
stripped threads and possible air or powder leaks.
1
2
3
4
4
5
Figure 8-13 50-lb Feed Hopper Fluidizing Plate Replacement
1. Body
2. Fluidizing plate
3. Plenum
4. O-ring gaskets
5. Nylon screws
Summary of Contents for Encore XL Powder
Page 8: ...2021 Nordson Corporation 1607027 01 ii Change Record...
Page 12: ...2021 Nordson Corporation 1607027 01 1 4 Safety...
Page 51: ...2021 Nordson Corporation 1607027 01 4 9 Setup 6 5 Figure 4 5 Pneumatic Controls 2 of 2...
Page 60: ...2021 Nordson Corporation 1607027 01 5 8 Operation...
Page 136: ...2021 Nordson Corporation 1607027 01 9 34 Parts...
Page 146: ...2021 Nordson Corporation 1607027 01 10 10Options...
Page 148: ...2021 Nordson Corporation 1607027 01 11 2 Pneumatic and Electrical Diagrams...
Page 149: ......
Page 150: ......
Page 151: ......
Page 152: ......
Page 153: ...ON OFF...
Page 154: ......