© 2021 Nordson Corporation
2-19
Air Pressures
Function
Recommended Pressure
Lift Cylinder Up
Lance: 4.1 bar (60 psi)
Lances: 4.8 bar (70 psi)
Lances: 5.5 bar (80 psi)
Lift Cylinder Down
3.4 bar (50 psi)
Lift Cylinder Flow Control Valves
6 seconds full travel both directions
Purge Air
6.2 bar (90 psi)
Lance Purge Clamp Cylinder(s)
3.4−4.1 bar (50−60 psi)
Clamp Cylinder Flow Control Valves 3 seconds full travel both directions
Feed Hopper Fluidizing
0.3−0.7 bar (5−10 psi) (see Note)
Lance Fluidizing
0.3−0.7 bar (5−10 psi) (see Note)
NOTE:
Adjust fluidizing air as needed. Powder should be gently boiling, without
geysering.
Sieves
Available Sieve Screens
381 mm (15 inch) Sieve:
864 Micron, 20 mesh without ultrasonics (standard)
381 Micron, 40 mesh without ultrasonics
234 Micron, 60 mesh, without ultrasonics
178 Micron, 80 mesh with ultrasonics
140 Micron, 100 mesh with ultrasonics