© 2021 Nordson Corporation
2-6
Lift Assembly
(contd)
When the cylinder moves the lance up, the lance down circuit is vented, allowing the
lance up circuit air to push the piston up. When the cylinder moves the lance down, the
lance up circuit is vented, allowing the lance down circuit air to push the piston down.
The flow control valves installed in the cylinder air ports control the travel speed of the
piston rod. Three proximity sensors mounted on the cylinder sense when the cylinder
piston is in the hopper, box empty, or purge positions.
2
LIFT CYLINDER
FLOW CONTROL
VALVE 1
REGULATORS
LANCE DOWN
LANCE UP
FLOW CONTROL
VALVE 2
6mm
2
2
1
1
1
1
6mm
6mm
NINE-STATION CONTROL MANIFOLD
CYLINDER LOCKED WHEN VENTED
LANCE DOWN WHEN VENTED
LANCE UP
WHEN VENTED
LOCK
2
2
2
3
R1
R2
1
4
5
6
1
3
8
7
Figure 2-5 Lance Lift Assembly
1. Flow control valves
2. Proximity sensors
3. Lift cylinder
4. Locking mechanism
5.
Support block/flange
6. Lift plate with wheels
7. Carriage stop
8. Linear V-guide
Summary of Contents for Encore XL Powder
Page 8: ...2021 Nordson Corporation 1607027 01 ii Change Record...
Page 12: ...2021 Nordson Corporation 1607027 01 1 4 Safety...
Page 51: ...2021 Nordson Corporation 1607027 01 4 9 Setup 6 5 Figure 4 5 Pneumatic Controls 2 of 2...
Page 60: ...2021 Nordson Corporation 1607027 01 5 8 Operation...
Page 136: ...2021 Nordson Corporation 1607027 01 9 34 Parts...
Page 146: ...2021 Nordson Corporation 1607027 01 10 10Options...
Page 148: ...2021 Nordson Corporation 1607027 01 11 2 Pneumatic and Electrical Diagrams...
Page 149: ......
Page 150: ......
Page 151: ......
Page 152: ......
Page 153: ...ON OFF...
Page 154: ......