Problem
Possible Cause
Corrective Action
15. Feed center low
powder level alarm
buzzer on
Alarm buzzer delay timer
has run out, level sensor
not detecting powder
Alarm buzzer timer starts when the transfer pump turns on. If
the timer runs out and the level sensor has still not detected
powder, then the alarm buzzer is turned on. The timer default is
3 minutes.
To turn off the buzzer, turn the Purge switch to Gun Purge
momentarily.
Problem with powder
supply or virgin transfer
pump
Refer to problems related to powder, sieve, or pump.
16. Color change does
not start when Color
Change switch
turned on, light off
E-Stop button pressed
Reset E-Stop button.
Exhaust fan not running,
or fan interlock circuit
defective
Turn on exhaust fan. Check fan interlock wiring between feed
center panel and main system panel.
Color Change switch or
wiring defective
No signal from switch to controller. Check switch and wiring,
repair or replace as needed.
PLC not initiating color
change sequence.
Check PLC operation. Contact your Nordson representative or
technical support center for help.
17. Color change does
not start with Color
Change switch
turned on, light on
Parts still in booth
Encore Engage system tracks parts through booth and will
delay color change start until parts clear booth. Booth length is
configurable through Encore Engage Configuration.
Encore Engage gun
positioners not in manual
or auto mode
Set the gun positioners to either manual or auto mode.
Encore Engage gun
positioner controller
did not receive Color
Change start signal from
feed center
The feed center passes signals for color change to the gun
positioner controller which then communicates with the Encore
Engage system.
Check the wiring and connections between the feed center
control panel and the gun positioner controller.
Reciprocator not in auto
mode
Reciprocator must be in auto mode for color change cycle to
start.
Set the reciprocator to auto mode.
Continued...
Summary of Contents for Encore XL Powder
Page 8: ...2021 Nordson Corporation 1607027 01 ii Change Record...
Page 12: ...2021 Nordson Corporation 1607027 01 1 4 Safety...
Page 51: ...2021 Nordson Corporation 1607027 01 4 9 Setup 6 5 Figure 4 5 Pneumatic Controls 2 of 2...
Page 60: ...2021 Nordson Corporation 1607027 01 5 8 Operation...
Page 136: ...2021 Nordson Corporation 1607027 01 9 34 Parts...
Page 146: ...2021 Nordson Corporation 1607027 01 10 10Options...
Page 148: ...2021 Nordson Corporation 1607027 01 11 2 Pneumatic and Electrical Diagrams...
Page 149: ......
Page 150: ......
Page 151: ......
Page 152: ......
Page 153: ...ON OFF...
Page 154: ......