© 2021 Nordson Corporation
4-2
Feed Center Function Settings
(contd)
Screen
Function
Description
Default
SCREEN 4
HDLV Pump Purge
Pulse Cycle Rate
Sets the on/off cycle rate for the
reclaim and virgin HDLV transfer
pump purge cycle. The purge cycle is
active while the pump purge duration
timer is running.
0.25
seconds
SCREEN 5
HDLV Pump Purge
Duration
Sets the duration for the reclaim and
virgin HDLV transfer pump purge
cycle. The purge cycle stops when the
duration timer runs out.
45.00
seconds
SCREEN 6
Gun Purge Pulse “ON”
Duration
Gun Purge Pulse “OFF”
Duration
Gun Purge Duration Per
Bank
Sets the pulse duration of the internal
gun purge during the gun purge cycle.
The cycle is active while the gun
purge duration timer is running.
Sets the duration of the delay
between internal gun purge pulses
during the gun purge cycle. The
cycle is active while the gun purge
duration timer is running.
Sets the duration for the purge cycle
for each purge bank. The purge cycle
stops when the duration timer runs
out.
0.50
seconds
1.30
seconds
45.00
seconds
SCREEN 7
Gun Purge
Bank Quantity
Configures the gun purge bank
quantity per system. The maxi-
mum number of gun purge banks
is three.
2
Summary of Contents for Encore XL Powder
Page 8: ...2021 Nordson Corporation 1607027 01 ii Change Record...
Page 12: ...2021 Nordson Corporation 1607027 01 1 4 Safety...
Page 51: ...2021 Nordson Corporation 1607027 01 4 9 Setup 6 5 Figure 4 5 Pneumatic Controls 2 of 2...
Page 60: ...2021 Nordson Corporation 1607027 01 5 8 Operation...
Page 136: ...2021 Nordson Corporation 1607027 01 9 34 Parts...
Page 146: ...2021 Nordson Corporation 1607027 01 10 10Options...
Page 148: ...2021 Nordson Corporation 1607027 01 11 2 Pneumatic and Electrical Diagrams...
Page 149: ......
Page 150: ......
Page 151: ......
Page 152: ......
Page 153: ...ON OFF...
Page 154: ......