4-1
© 2021 Nordson Corporation
Section 4
Setup
WARNING:
Allow only qualified personnel to perform the following tasks. Follow the
safety instructions in this document and all other related documentation.
Feed Center Function Settings
The feed center functions are controlled by a PLC inside the feed center control panel,
on the front of the feed center. The following function values are programmed into the
controller at the factory and can be adjusted as needed for the application.
Screen
Function
Description
Default
SCREEN 1
Welcome Screen
Displays current version and date
SCREEN 2
Virgin Powder Transfer
Delay
Sets the time to wait after the powder
level falls below the level sensor before
turning on the virgin transfer pump. The
virgin pump and sieve must be on. This
delay prevents frequent pump starts and
stops (chattering).
40.00
seconds
SCREEN 3
Low Powder Alarm
Delay
Sets the time to wait after the powder
level in the feed hopper falls below the
level sensor before turning on the alarm
buzzer. The virgin transfer pump must be
on. If powder is detected before the timer
runs out, the timer is cancelled. The
buzzer can be silenced by switching Gun
Purge on momentarily.
3.00
minutes
Continued...
Summary of Contents for Encore XL Powder
Page 8: ...2021 Nordson Corporation 1607027 01 ii Change Record...
Page 12: ...2021 Nordson Corporation 1607027 01 1 4 Safety...
Page 51: ...2021 Nordson Corporation 1607027 01 4 9 Setup 6 5 Figure 4 5 Pneumatic Controls 2 of 2...
Page 60: ...2021 Nordson Corporation 1607027 01 5 8 Operation...
Page 136: ...2021 Nordson Corporation 1607027 01 9 34 Parts...
Page 146: ...2021 Nordson Corporation 1607027 01 10 10Options...
Page 148: ...2021 Nordson Corporation 1607027 01 11 2 Pneumatic and Electrical Diagrams...
Page 149: ......
Page 150: ......
Page 151: ......
Page 152: ......
Page 153: ...ON OFF...
Page 154: ......