© 2021 Nordson Corporation
8-21
See Figure 8-17
for steps 5 - 8 when replacing or retrofitting a 50Hz vibratory table motor
for the feed center.
5. Install the weight blades that were removed. Turn
(1)
weight blade on each shaft end
to the opposite position as shown.
6.
Make sure that the weight blades are in the same configuration at both ends of the
motor.
ONE
weight blade must be rotated at each end. Tighten both shaft nuts
securely to 74-78 ft-lb.
7.
Install the end caps with the flat area on the cap aligned with the flat area on the
mounting flange.
8. Tighten the screws to 4 ft-lb.
Step 7
Step 5
Step 5 - 6
Step 7 - 8
FLAT AREA
FLAT AREAS ALIGNED
Figure 8-17
Vibrator Weight Adjustment, 50Hz, Steps 5−8