background image

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.

IN423500AV 1/05

Instruction Sheet

EZ5000 Series Sprayers

Special Priming

Instructions

Freeing valves when stuck

BUILT TO LAST

For parts, manuals, product & service information

visit 

www.chpower.com

© 2005 Campbell Hausfeld/Scott Fetzer

Before attempting this procedure, make sure you have read all manuals and safety

information included with your paint sprayer. Failure to do so could result in death or serious injury.

Turn off unit and disconnect power before attempting this procedure. Failure to do so

could result in death or serious injury from electrical shock.

Freeing Inlet Valve

1. If there is a hose clamp on suction hose, loosen clamp and remove hose.

2. Insert screwdriver into inlet and push on spring-loaded pin until pin is moving freely. Do not push too hard.

Freeing Outlet Valve

1. With wrench, remove outlet valve.

2. Turn valve upside down.

3. With screwdriver, push on ball inside valve until ball is moving freely. Do not push too hard.

4. Reinstall outlet valve and tighten with wrench until snug. Do not overtighten.

!

WARNING

!

WARNING

Outlet Valve

Inlet Valve

Suction Hose

(Outlet valve shown
upside down.)

Push here to free
up outlet valve.

For replacement parts
or technical assistance,
call 1-800-626-4401

Reviews: