Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
IN423500AV 1/05
Instruction Sheet
EZ5000 Series Sprayers
Special Priming
Instructions
Freeing valves when stuck
BUILT TO LAST
For parts, manuals, product & service information
visit
www.chpower.com
© 2005 Campbell Hausfeld/Scott Fetzer
Before attempting this procedure, make sure you have read all manuals and safety
information included with your paint sprayer. Failure to do so could result in death or serious injury.
Turn off unit and disconnect power before attempting this procedure. Failure to do so
could result in death or serious injury from electrical shock.
Freeing Inlet Valve
1. If there is a hose clamp on suction hose, loosen clamp and remove hose.
2. Insert screwdriver into inlet and push on spring-loaded pin until pin is moving freely. Do not push too hard.
Freeing Outlet Valve
1. With wrench, remove outlet valve.
2. Turn valve upside down.
3. With screwdriver, push on ball inside valve until ball is moving freely. Do not push too hard.
4. Reinstall outlet valve and tighten with wrench until snug. Do not overtighten.
!
WARNING
!
WARNING
Outlet Valve
Inlet Valve
Suction Hose
(Outlet valve shown
upside down.)
Push here to free
up outlet valve.
For replacement parts
or technical assistance,
call 1-800-626-4401