LEDs on the ESM canister
Table 24: LEDs on the ESM canister
Location
LED
Color
On
Off
1
Host Link 1
Fault
Amber
At least one PHY of the
four connectors is
working, but another
PHY cannot establish
the same link to the
device connected to the
Host IN port connector.
No link error has
occurred.
2
Host Link 1
Active
Green
At least one of the four
PHYs in the In port is
working, and a link
exists to the device
connected to the Host In
connector.
A link error has
occurred.
3
Host Link 2
Fault
Amber
At least one PHY of the
four connections is
working, but another
PHY cannot establish
the same link to the
device connected to the
Host In port connector.
No link error has
occurred.
4
Host Link 2
Active
Green
At least one of the four
PHYs in the IN port is
working, and a link
exists to the device
connected to the Host In
connector.
A link error has
occurred.
5
Ethernet
Link Active
Green
The link is up. (The
LED blinks when there
is activity.)
The link is not active.
6
Ethernet
Link Rate
Green
There is a 100BASE-T
rate.
There is a 10BASE-T
rate.
Step 10 - Turning on the power and checking for problems in a controller-drive tray configuration | 117
Summary of Contents for E2760