383
OS or T&D Starting
OS or T&D Starting status
T&D Running
T&D Running status
OS Running
OS Running status
Stopping
Shutdown (mounting) in progress status
Handling Fault
Handling Fault status
Handling DP
Handling DP status
Power On Failed
Stopped status with power-on failure
BIOS
: BIOS version
(3) Power Consumption by BaseModule
Display base module status and power consumption.
Resource : Base module name (link to resource Web page)
Power
: Power status
Display (value)
Description
Off
DC power of all Servers is OFF
On
DC power of at least 1 Server is ON
Watt
: Power consumption
Health
: Overall base module status
Display (value)
Description
Normal
No failure occurrence, or Correctable Error only
Non-Critical
Recoverable Error occurrence
Maintenance required inside the server
Critical
Fatal Error occurrence
Maintenance required inside the server
1.2 Monitoring
Monitoring is displayed by selecting
“Monitoring”
from the menu on the left side of the screen.
The following item status of the system can be checked in
Monitoring
.
(1) Sensor Readings
(2) Event Log
Summary of Contents for Express 5800
Page 73: ...73 Memo ...
Page 279: ...Hardware 279 3 BIOS Menu screen is displayed ...
Page 339: ...Hardware 339 3 BIOS will start Select Save Exit then press Enter ...
Page 444: ...444 Part Number Part number FRU File ID FRU file ID Asset Tag Asset management tag ...
Page 573: ...573 Memo ...
Page 583: ...Software 583 Memo ...
Page 690: ...Operation and Maintenance 690 Memo ...
Page 719: ...XXIX Memo ...