Operation and Maintenance
616
Failure Analysis Procedure
As described in the Chapter 2
“Hardware,”
the server is configured with CRU and FRU which
are replaceable modules/units in the installation environment of the customer.
This section describes the analyzing procedure of CRU (Customer
Replacement Unit).
When the status LED of EXPRESSSCOPE®
Monitor lights other than green during the server
operation, except when the power is off, the status indicates the server has failure.
In this case, select
“View Faults”
in the EXPRESSSCOPE® Monitor to check if there is any
failure or failure indication.
FRU displayed on
“View Faults”
is the highest possibility (or suspected) parts of the cause of
failure.
Example) The following example shows the FRU name as PSU, the power supply unit. From the
FRU Location, the power supply unit of the slot 3 is the most suspected one.
• FRU Name
: PSU
…Power Supply Unit
• Server Number
:
SVR1,2
…Indicating the part belongs to the
Server 1 and the
Server2 (shared) (
A1080a-D
model only).
• FRU Location
:
PSU3
…Indicating the position is the Power Supply Unit #3.
If the FRU Name displayed on
“View Faults”
corresponds any of the following four types, the
parts can be replaced by customer. Refer to
“Hardware”
for the replacement procedure.
• CRU (Customer
Replacement Unit) List
No. Abbreviated
name
Name
Described name on this
guide
1
HDD
Hard Disk Drive
Hard disk drive
2
PSU
Power Supply Unit
Power supply unit
3 DVD
Digital Versatile Disk
DVD
drive
4
FAN
FAN Module
FAN module
Further analysis is required if nothing is shown on
“View Faults”
of EXPRESSSCOPE® Monitor,
or if the displayed abbreviation is not on the above list.
P S U
S V R 1 , 2
↑
P S U 3
S e e M a i n t
G u i d e
↓
FRU Name
FRU Location
Server Number
Summary of Contents for Express 5800
Page 73: ...73 Memo ...
Page 279: ...Hardware 279 3 BIOS Menu screen is displayed ...
Page 339: ...Hardware 339 3 BIOS will start Select Save Exit then press Enter ...
Page 444: ...444 Part Number Part number FRU File ID FRU file ID Asset Tag Asset management tag ...
Page 573: ...573 Memo ...
Page 583: ...Software 583 Memo ...
Page 690: ...Operation and Maintenance 690 Memo ...
Page 719: ...XXIX Memo ...