Hardware
330
Patrol Read
The patrol read gives the read & verify test in the entire area of HDDs. It can be performed
for all HDDs assigned to virtual disks and hot-spares.
The Patrol Read allows subsequent defects of HDDs to be detected and repaired.
For HDDs configuring redundant virtual disks or those assigned to hot-spares, error sectors
detected during Patrol Read can be repaired.
Consustency Check
The Consistency Check is used to check consistency among virtual drives. It is available for
redundant virtual drives except for RAID0.
Consistency Check can be performed through WebBIOS or Universal RAID Utility.
Consistency Check performs not only consistency check but also repair of error sectors.
Accordingly, it can be used as preventive maintenance.
IMPORTANT:
Note the following for the patrol read:
●
To change settings of Patrol Read, use Universal RAID Utility.
●
If the system is restarted while running Patrol Read, Patrol Read
resumes from that point.
IMPORTANT:
Note the following for Consistency Check:
●
During Consistency Check, the processing rate is decreased due to
heavy load.
●
If the system is restarted, the Consistency Check is aborted.
However, the Consistency Check resumes after restart.
●
For scheduled execution of Consistency Check, use WebBIOS.
Summary of Contents for Express 5800
Page 73: ...73 Memo ...
Page 279: ...Hardware 279 3 BIOS Menu screen is displayed ...
Page 339: ...Hardware 339 3 BIOS will start Select Save Exit then press Enter ...
Page 444: ...444 Part Number Part number FRU File ID FRU file ID Asset Tag Asset management tag ...
Page 573: ...573 Memo ...
Page 583: ...Software 583 Memo ...
Page 690: ...Operation and Maintenance 690 Memo ...
Page 719: ...XXIX Memo ...