Setting Hot Spare
Described below are procedures based on assumption:
Add a HDD to a RAID5 virtual disk configured with three HDDs and assign a newly added HDD
as Hot Spare.
1.
Start WebBIOS.
Make sure that the status for the added HDD is indicated as "UNCONF GOOD" in the Physical
Drives frame of the WebBIOS Home.
2.
Select "( ):1:5" (newly connected HDD) in [Physical Drives] and press
Enter
.
3.
The properties for Physical Drive is displayed.
4.
Select [Make Global HSP] or [Make Dedicated HSP] on the lower right of the screen, select
[Go] on the lower center of the screen, and press
Enter
.
Global HSP:
Indicates the Hot Spare available for all DGs.
Dedicated HSP: Indicates the Hot Spare available only for the specific DG.
You need to specify the target DG.
5.
The status for the newly connected HDD changes to "HOTSPARE".