7-36 Troubleshooting
ESM HAS Storage Service-related logs are recorded in the system event log:
o
Even though the mirror volume is actually built, when the system is highly loaded,
the following event logs may be recorded repeatedly. Since the system is highly
loaded, the status of SCSI slot and mirror disk cannot be retrieved, and incorrect
status is retrieved temporally, and these logs are recorded. If you can verify that
the mirror volume is established, there is no problem, so ignore them.
Source:
ESM HAS Storage Service
Type: Warning
Event ID:
601
Source:
ESM HAS Storage Service
Type: Information
Event ID:
602
Source:
ESM HAS Storage Service
Type: Information
Event ID:
402
The following event logs may be recorded during the system operation. This is
caused because there are internally two types of “Empty” status that shows that
disks are not loaded. For example, if disks do not exist in Slot 1 and Slot 4,
“Empty” simply indicates information. Also, if the disk where a volume is not
created exists in Slot 4, “Empty” of Slot 1 is just at the information level. If a
simple volume is created on the disk of Slot 4, “Empty” of Slot 1 is treated as the
warning level to secure the redundancy. In this case, check the volume creation
status, and configure the mirror volume.
Source:
ESM HAS Storage Service
Type: Warning
Event ID:
401
Description: Status of the SCSI Slot (ID:41/[Slot Number]) has changed from
Empty to Empty.
[Slot Number]: a number between 0 and 5
Source:
ESM HAS Storage Service
Type: Information
Event ID:
402
Description: Status of the SCSI Slot (ID:41/[Slot Number]) has changed from
Empty to Empty.
[Slot Number]: a number between 0 and 5
o
The following event log may be recorded while the server is starting. To start the
server, start one module and then another one, and make them duplex. For this
reason, if only one module has been started but the other one is starting, the status
of the SCSI adapter and the bus temporarily becomes Simplex and Offline
respectively. There is no problem if each status changes to Duplex after the duplex
operation completes. Because of this, right after the server is started and the event
that the status is changed to Duplex is registered when the duplex operation
completes, there are not any problem, so ignore it.
Summary of Contents for EXP320A
Page 15: ......
Page 22: ...Precautions for Use 1 3 Rack model Front Rear ...
Page 24: ...Precautions for Use 1 5 Water Cooling kit ...
Page 52: ...Precautions for Use 1 33 ء ข Δ ਢ ڼط ข س ऱధჾࢨਚᎽΔ ڇঁܛ অଥཚၴփՈ گ ፂଥ၄ ش Ζ ...
Page 68: ...General Description 2 13 Rack model with the front door open ...
Page 73: ...2 18 General Description Rear View Tower model ᴾ Rack model ...
Page 110: ...Windows Setup and Operation 3 15 7 Configure the mirror of the extended volume ...
Page 128: ...Windows Setup and Operation 3 33 4 The confirmation dialog box appears Click Yes button ᴾ ᴾ ...
Page 164: ...System Configuration 4 27 Exit Move the cursor onto Exit to display the Exit menu ...
Page 225: ...4 88 System Configuration This page is intentionally left blank ᴾ ...
Page 286: ...Installing and Using Utilities 5 61 Sample screen of Server Maintenance Utility ...
Page 327: ...6 14 Maintenance This page is intentionally left blank ...
Page 381: ...7 54 Troubleshooting This page is intentionally left blank ...
Page 424: ...Specifications A 3 ...
Page 425: ......