Troubleshooting 7-23
o
When you attempt to integrate the CPU module, the following message will be
recorded to the system event log and the CPU module may not be integrated. It
indicates that some kind of error has occurred when integrate the module. Contact
your sales agent, since device replacement will be required.
Source:
HasCtrl
Type:
Error
Event ID:
1003
Description: The driver failed to bind the CPU module. [Module[Module
Number]]
[Module Number] “#0” or “#1”
IO module is not integrated:
o
When you attempt to integrate the IO module that caused an error in the past, the
following message will be recorded to the system event log and the IO module will
not be integrated. In this case, contact your sales agent, since device replacement
will be required.
Source:
HasCtrl
Type:
Warning
Event ID: 1407
Description: The driver was not able to bind South Bridge. It has broken down in
the past. [Module[Module Number]]
[Module Number] “#0” or “#1”
Source:
HasCtrl
Type:
Warning
Event ID: 1405
Description: The driver was not able to bind PCI Express 0. It has broken down
in the past. [Module [Module Number]]
[Module Number] “#0” or “#1”
Source:
HasCtrl
Type:
Warning
Event ID: 1406
Description: The driver was not able to bind PCI Express 1. It has broken down
in the past. [Module [Module Number]]
[Module Number] “#0” or “#1”
o
When you attempt to integrate the IO module while PCI device is not completed to
separate, the following message will be recorded to the system event log and the IO
module will not be integrated. In this case, wait for a while and try to integrate IO
module again referring to Chapter 5 “Start and Stop of Components.”
Summary of Contents for EXP320A
Page 15: ......
Page 22: ...Precautions for Use 1 3 Rack model Front Rear ...
Page 24: ...Precautions for Use 1 5 Water Cooling kit ...
Page 52: ...Precautions for Use 1 33 ء ข Δ ਢ ڼط ข س ऱధჾࢨਚᎽΔ ڇঁܛ অଥཚၴփՈ گ ፂଥ၄ ش Ζ ...
Page 68: ...General Description 2 13 Rack model with the front door open ...
Page 73: ...2 18 General Description Rear View Tower model ᴾ Rack model ...
Page 110: ...Windows Setup and Operation 3 15 7 Configure the mirror of the extended volume ...
Page 128: ...Windows Setup and Operation 3 33 4 The confirmation dialog box appears Click Yes button ᴾ ᴾ ...
Page 164: ...System Configuration 4 27 Exit Move the cursor onto Exit to display the Exit menu ...
Page 225: ...4 88 System Configuration This page is intentionally left blank ᴾ ...
Page 286: ...Installing and Using Utilities 5 61 Sample screen of Server Maintenance Utility ...
Page 327: ...6 14 Maintenance This page is intentionally left blank ...
Page 381: ...7 54 Troubleshooting This page is intentionally left blank ...
Page 424: ...Specifications A 3 ...
Page 425: ......