Call Routing Mailbox
IntraMail for Aspire System Guide
Chapter 2: Features
◆
55
2
Related Features
The Call Routing Mailbox associates speci
fi
c dialing options (Dial Action Table) with an Answer Table.
The Automated Attendant can automatically answer the telephone system’s incoming calls, play an
Instruction Menu message, and provide dialing options to callers.
The Call Routing Mailbox provides the dialing instructions (Dial Action Table) and announcements to
Automated Attendant Callers.
De
fi
nes the dialing options for the Call Routing Mailbox chosen by the active Answer Table.
Master Mailboxes can provide an additional 16 Call Routing Mailboxes.
The System Administrator can record the Instruction Menu for a Call Routing Mailbox. See
Operation
below.
Programming
Step 1
Set up the Call Routing Mailbox.
1.1
47-07-01: Routing Mailbox Active
- Enter
1
(Yes) to enable the selected Routing Mailbox.
✔
By default, all Routing Mailboxes are enabled (
1
).
1.2
47-07-02: Routing Mailbox Type
- Enter
1
to assign the mailbox as a Call Routing Mailbox.
✔
By default, Routing Mailboxes 1-8 are Call Routing Mailboxes and 9-16 are Announce-
ment Mailboxes.
Step 2
To record an Instruction Menu for the Call Routing Mailbox:
2.1
See
Operation
below.
✔
The default Instruction Menu is:
If you are calling from a touch tone phone . . .
Step 3
To assign which Dial Action Table will provide dialing options for this Call routing Mailbox:
3.1
- Enter the Dial Action Table (e.g., 1) that will provide the dialing options.
✔
By default, all Call Routing Mailboxes use Dial Action Table 1.
Step 4
To change the amount of time Automated Attendant callers have to dial options:
4.1
4.2
47-08-03: Time Limit for Dialing Commands
- Enter the new timeout duration (0-99 seconds).
✔
By default, Automated Attendant callers have 5 seconds to dial commands.
4.3
If the caller waits too long to dial:
- When the associated Dial Action Table has a Timeout action programmed, the caller routes
to that destination.
- When the associated Dial Action Table does not have a Timeout action programmed, the
Instruction Menu repeats 3 times and then IntraMail hangs up.
Step 5
To set the Maximum Length of Instruction Menus:
5.1
47-01-03: Subscriber Message Length
- This sets the maximum message length (
1-4095
seconds) for Instruction Menus.
✔
The default setting is
120
seconds.