Installation
1-52 Manual # 42-02-2P26
Hoistway Learn (Landing System Learn)
After installing the leveling and terminal magnets, you will need to perform a learn operation to
learn floor and terminal positions. If floor level magnets have not been positioned accurately
enough, any offset can be adjusted in software (+/- 1 inch).
1. Place car on Test and Machine Room Inspection using switches on SCE-CPU.
2. Set the FLT BYPASS jumper in the BYPASS position.
3. Select the UTILS menu. Select CONSTRUCT AND BYPASS FAULTS.
4. Select AUTOMATIC FAULT BYPASS DISABLED; press OK to ENABLE. Press EXIT.
Faults are now bypassed.
5. Move car on inspection to about six (6) or more inches above bottom terminal landing.
6. Select LANDING SYSTEM UTILITIES. Select HOISTWAY LEARN (LANDING SYSTEM
LEARN). Press LEARN.
7. Set Machine Room Inspection switch to NORM. The screen will display FINDING BOT-
TOM, followed by BOTTOM FOUND. The car will then begin to run up the hoistway.
During the run, the screen will display LEARNING. Once the top floor is learned the screen will
display FINALIZING, followed by STORING HOISTWAY, and finally DONE STORING HOIST-
WAY.
8. Press DONE. Press EXIT. Press EXIT on the following screens until the UTILS home
menu appears
9. Select CONSTRUCT AND BYPASS FAULTS. Press AUTOMATIC FAULT BYPASS
ENABLED. Press OK to disable fault bypass.
10. Move the FAULT BYPASS jumper to the NORM position. Faults are no longer bypassed.
Tuning
For the best possible control through the speed range, the drive may need to be tuned to the
characteristics of the motor according to the instructions in the drive manual.
Magnetek HPV 900 Series 2
Refer to the Appendix of the Magnetek drive manual and follow the Adaptive Tune instructions
provided.
TORQMAX F5
Refer to Motor Learn in the TORQMAX F5, v3.21 manual.