Troubleshooting Reference
2-77
element
TM
Series
Parameter Storage Fault (130)
A fault occurred while parameters were being stored. Cannot be
bypassed. The car will not be allowed to move.
Correction:
1. If fault occurred while updating software, reset processor C, repeat
software update.
2. If fault does not clear, see error code under STORAGE ERROR (SPB
DIAG, SPB NUMERIC). Contact MCE.
Passcode Enabled (451)
While the passcode remains active this message will be displayed on the
Home screen and the car will not respond to hall calls. Please refer to
Passcode (Restricted Mode) on page 1-69
.
Passenger Mode (0)
Passenger mode active.
PHE Antinuis. Disabled (351)
Informational. PHE antinuisance feature has been disabled.
PHE Antinuisance (350)
Informational. The photo eye antinuisance call threshold has been
achieved; all car calls are canceled. Self resetting. Cannot be bypassed.
PHE Bypass (32)
The door photo eye/infrared detector has been active for a timer deter-
mined period and is now being bypassed. Fault-bypassed in Construction.
System Verifies:
- Door Flags = Photo Eye Bypassed
Correction:
1. If in error, verify no input programmed PHE.
2. Check the PHE input.
3. See related Stuck PHE and Bypass Stuck PHE events.
PHE Fail (33)
The door photo eye/infrared detector has failed. Issued when the photo
eye has been continuously activated for a predetermined time while the
doors are fully closed. Fault-bypassed in Construction.
System Verifies:
- Door Flags = Photo Eye Failed
Correction:
1. If in error, verify no input programmed if PHE not used.
2. Check that input is properly wired and programmed.
3. System IO > Programmed Inputs > PHE.
PLD RX Communication (237)
No communication received from PLD. Car not allowed to move. Cannot
be bypassed.
PLD RX Message (239)
Message from PLD not properly formed. Car not allowed to move. Cannot
be bypassed.
PLD TX Communication (236)
Unable to communicate with PLD. Car not allowed to move. Cannot be
bypassed.
PLD TX Message (238)
Message sent to PLD not properly formed. Car not allowed to move. Can-
not be bypassed.
PLD Write Fault (Edge) (218)
Initiated by LS-EDGE-EL landing system. The ETS trip value cannot be
written to the landing system PLD. Cannot be bypassed.
Correction:
1. PLD hardware has failed or software is not loaded.
2. Verify software versions for LS-EDGE-EL.
PM Failed to Turn Off (254)
Traction Only. The primary motor contactor failed to drop out at the end
of a run. Cannot be bypassed.
Correction:
1. Check PMP LED on SCE-CPU IDC connector.
PM Failed to Turn On (255)
Traction Only. The primary motor contactor did not pick at the beginning
of a run. Cannot be bypassed.
Correction:
1. Check PM contactor coil.
Table 2.15 Touch Screen Event Listings
Event
Description