S-Curve
-
Standard Start Jerk
: Defines the transition from zero speed to full accel-
eration. As this value increases, the profile transitions more quickly from
starting to maximum acceleration. Values typically range from 4.0 to 8.0.
-
Standard Roll Jerk
: Determines how quickly the profile transitions from
maximum to zero acceleration and zero to maximum deceleration. As Roll
Jerk increases, the profile transitions more quickly. Lower values provide
greater comfort but are harder to fit into the shortest one-floor-runs. We
recommend you identify the shortest full height floor and use it when test-
ing parameter values. Typical values range upwards from a minimum of 4.0.
-
Standard Stop Jerk
: Defines the transition from deceleration to Leveling
Speed. As stop jerk increases the profile transitions more quickly from
deceleration to leveling speed.
-
Standard Acceleration
: Determines the maximum acceleration for the
profile and the maximum current delivered by the drive during acceleration.
Maximum value is typically 4.0; minimum is usually not less than 2.5.
Higher values than 4.0 are possible but do not yield significant improve-
ments in performance.
-
Standard Deceleration
: Determines the maximum deceleration for this
profile. The maximum value is typically 4.0 and the minimum is usually not
less than 2.0 with common values raging from 2.75 to 3.75. The value of
deceleration is usually slightly less than the value of acceleration.
-
Alternate Start Jerk
: Defines the transition from zero speed to full accel-
eration. As this value increases, the profile transitions more quickly from
starting to maximum acceleration. Values typically range from 4.0 to 8.0.
-
Alternate Roll Jerk
: Determines how quickly the profile transitions from
maximum to zero acceleration and zero to maximum deceleration. As Roll
Jerk increases, the profile transitions more quickly. Lower values provide
greater comfort but are harder to fit into the shortest one-floor-runs. We
recommend you identify the shortest full height floor and use it when test-
ing parameter values. Typical values range upwards from a minimum of 4.0.
Table 2.1 Touchscreen Organization and Content
Tab
Subtab
Description
Leveling Speed
Zero Speed
Correction Speed
Proximity Distance
Standard
Alternate
Manual
Danger
Start Jerk
Stop Jerk
Roll Jerk
Roll Jerk
Acceleration
Deceleration
CONFIG