Configuration and Troubleshooting
2-72 Manual # 42-02-2P26
Inspection Invalid (99)
Controller unable to establish proper mode of Inspection. Fault-bypassed
in Construction/Inspection.
System Verifies:
- Mode of Operation = Inspection Invalid
Correction:
1. Verify all inspection inputs mechanically and electrically.
Invalid Access Zone (369)
Car has been placed on Inspection Access but is outside the selected
access zone.
If in error:
1. Verify car position.
2. Verify CONFIG 02 > HOISTWAY SETUP > TOP|BOTTOM ACCESS DIS-
TANCE.
3. Verify switch wiring.
Invalid Mode (6)
The car is in an invalid operating mode. Appears temporarily at power up
and is immediately replaced with the actual operating mode. If it
appeared during normal operation, a running car would perform an
emergency stop and shut down. A stopped car would remain stopped and
shut down. Cannot be bypassed.
System Verifies:
- Mode of Operation = OpModeInvalid or OpModeInspectionInvalid
Correction:
1. Cycle power to the controller.
2. Contact MCE; possible defective SCE-CPU board.
IO Terminal Mapping Flt (341)
More than one spare input or output are programmed to the same hard-
ware IO terminal.
Correction:
1. Verify spare inputs and outputs.
Leveling Overspeed (425)
Leveling overspeed detected. Car will perform an emergency stop and be
removed from service.
Correction:
1. Verify landing system connections and configuration (CONFIG2 > Sys-
tem Control Parameters > Leveling Overspeed).
LLI Antinuisance (352)
Informational. The light load antinuisance call threshold has been
achieved; additional car calls are being canceled. Self resetting. Cannot
be bypassed.
LS Config Error (427)
Generated when Level Distance is not greater than Level Dead Zone Dis-
tance and/or Relevel Distance is not greater than Relevel Dead Zone Dis-
tance. Car is shut down. The fault is non-latching.
Correction:
Adjust Config 02 > System Control Parameters mentioned above.
LS-EDGE Boot Correction (364)
If controller loses power, LS-EDGE continues to record position for a short
period of time. When power is regained, if LS-EDGE determines that car
has moved from last recorded position, it will perform a terminal sync to
correct.
Correction:
1. Cycle power. LS-EDGE should clear the message.
2. Verify brake is holding 125% of rated load.
LS-EDGE Boot with Error (363)
Initiated by LS-EDGE-EL landing system. LS-EDGE has discovered an
error while booting up after a power on or system reset. All calls will be
canceled; doors will remain closed. Cannot be bypassed.
Table 2.15 Touch Screen Event Listings
Event
Description