8 - 6
8 OUTPUT MODULE
(2) Control details
(a) The roller has no current value.
However, when it switches from the virtual mode to real mode, it reaches the
current value corresponding to the position moved in the virtual mode.
• The current value is a ring address within the range of -2147483648 (-2
31
)
to 2147483647 (2
31
-1) [PLS].
(2
31
-1)
-2
31
Current value
(b) Backlash compensation processing is continued with the settings value of
fixed parameters even if it switches the real mode/virtual mode.
(c) The roller cycle speed can be monitored using MT Developer2 and the roller
cycle speed storage register.
Refer to Section 8.1.2 for the calculation formula of roller cycle speed, and
refer to Section 4.2.1 for details of the roller cycle speed storage register.
8.1.2 Parameter list
The roller parameters are shown in Table 8.1 and the parameters shown in this table
are explained in items (1) to (6) below.
Refer to the help of MT Developer2 for the roller parameter setting method.
Table 8.1 Roller Parameter List
No.
Setting item
Default
Setting range
1 Output axis No.
0
Q173DSCPU/Q173DCPU(-S1) : 1 to 32
Q172DSCPU
: 1 to 16
Q172DCPU(-S1)
: 1 to 8
2 Output
unit
mm
mm
inch
3 Roller diameter (L)
0
0.1 to 214748364.7
[µm]
0.00001 to
21474.83647 [inch]
4
Number of pulses per roller
revolution (N
L
)
0
1 to 2147483647 [PLS]
5 Permissible droop pulse value 6553500
1 to 1073741824 [PLS]
6 Speed limit value (V
L
) 0
0.01 to 6000000.00
[mm/min]
0.001 to 600000.000
[inch/min]
7
Torque limit value setting
device (1 word)
—
-(300[%]) / word device (D, W, #, U \G)
8 Comment
None
32
characters
(1) Output unit
(a) This device is used to set the unit ([mm]/[inch]) of roller.
(b) The unit (unit in the fixed parameter) for the axis which execute the roller
setting in the real mode is permissible to use the any of [mm], [inch],
[degree] and [PLS].
Summary of Contents for Q Series
Page 1: ......
Page 19: ...A 18 MEMO ...
Page 129: ...4 90 4 POSITIONING DEDICATED SIGNALS MEMO ...
Page 134: ...5 5 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Page 139: ...5 10 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Page 163: ...6 24 6 DRIVE MODULE MEMO ...
Page 201: ...7 38 7 TRANSMISSION MODULE MEMO ...
Page 257: ...9 12 9 REAL MODE VIRTUAL MODE SWITCHING AND STOP RE START MEMO ...
Page 267: ...10 10 10 AUXILIARY AND APPLIED FUNCTIONS MEMO ...