8 - 11
8 OUTPUT MODULE
(3) Permissible droop pulse value
(a) This device is used to set the permissible droop pulse value of deviation
counter.
(b) The deviation counter value is continually checked, and if it becomes larger
than the permissible droop pulse value, the error detection signal
(M2407+20n) turns on.
However, since the ball screw axis operation continues, execute the error
processing by user side.
(4) Upper/lower stroke limit value
(a) This device is used to set the stroke range in the virtual mode.
(b) When it exceeds the stroke range during operation, the error detection signal
(M2407+20n) turns on.
However, a stop processing of ball screw axis is not executed.
(5) Speed limit value (V
L
)
(a) This device is used to set the maximum speed of ball screw axis.
(b) Set the speed limit value within the following range.
1) Unit : [mm]
V
L
10
4
N
P
1
60 P
2147483647 [PLS/s]
2) Unit : [inch]
V
L
10
5
N
P
1
60 P
2147483647 [PLS/s]
(c) When the ball screw axis speed exceeds the speed limit value, the error
detection signal (M2407+20n) turns on.
However, the ball screw axis speed is not clamped.
V
Even if the speed limit value is exceeded,
it controls with the setting speed.
Speed limit value
t
Summary of Contents for Q Series
Page 1: ......
Page 19: ...A 18 MEMO ...
Page 129: ...4 90 4 POSITIONING DEDICATED SIGNALS MEMO ...
Page 134: ...5 5 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Page 139: ...5 10 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Page 163: ...6 24 6 DRIVE MODULE MEMO ...
Page 201: ...7 38 7 TRANSMISSION MODULE MEMO ...
Page 257: ...9 12 9 REAL MODE VIRTUAL MODE SWITCHING AND STOP RE START MEMO ...
Page 267: ...10 10 10 AUXILIARY AND APPLIED FUNCTIONS MEMO ...
Page 352: ......