4 - 40
4 POSITIONING DEDICATED SIGNALS
(2) Virtual servo start accept flag (M2001 to M2032)
........................ Status signal
(a) This flag turns on when the servo program is started. The start accept flag
corresponding to an axis specified with the servo program turns on.
(b) The ON/OFF processing of the start accept flag is shown below.
1) When the servo program is started using the Motion SFC program or
Motion dedicated PLC instruction (D(P).SVST), the start accept flag
corresponding to an axis specified with the servo program turns on and
it turns off at the positioning completion. This flag also turns off when it is
made to stopping on the way.
(When it is made to stop on the way by the speed change to speed "0",
this flag remains on.)
Normal positioning completion
Dwell time
ON
OFF
ON
OFF
V
Positioning
completion
t
Servo program start
Start accept flag
(M2001+n)
Positioning complete
signal (M4001+20n)
Positioning start
complete signal
(M4000+20n)
Servo program start
Start accept flag
(M2001+n)
Positioning complete
signal (M4001+20n)
Positioning start
complete signal
(M4000+20n)
Positioning stop during control
ON
OFF
V
t
OFF
ON
Positioning
start
Positioning
stop
completion
2) This flag turns on at the positioning control by turning on the JOG start
command (M4802+20n or M4803+20n), and turns off at the positioning
stop by turning off the JOG start command.
3) This flag turns on during the manual pulse generator enable (M2051 to
M2053: ON), and turns off at the manual pulse generator disable
(M2051 to M2053: OFF).
4) This flag turns on during a current value change by the CHGA
instruction of servo program or Motion dedicated PLC instruction
(D(P).CHGA), and turns off at the completion of the current value
change.
OFF
ON
CHGA instruction
Start accept flag
(M2001 to M2032)
Current value changing
processing
Turns off at the completion of
current value change.
Summary of Contents for Q Series
Page 1: ......
Page 19: ...A 18 MEMO ...
Page 129: ...4 90 4 POSITIONING DEDICATED SIGNALS MEMO ...
Page 134: ...5 5 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Page 139: ...5 10 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Page 163: ...6 24 6 DRIVE MODULE MEMO ...
Page 201: ...7 38 7 TRANSMISSION MODULE MEMO ...
Page 257: ...9 12 9 REAL MODE VIRTUAL MODE SWITCHING AND STOP RE START MEMO ...
Page 267: ...10 10 10 AUXILIARY AND APPLIED FUNCTIONS MEMO ...
Page 352: ......