4 - 21
4 POSITIONING DEDICATED SIGNALS
(13) Virtual mode continuation operation disable warning signal
(M2418+20n) .............................................................. Status signal
When the difference between the final servo command value in previous virtual
mode last time and the servo current value at virtual mode switching next time
exceeds the "Allowable travel value during power off (× Number of feedback
pulses)" set in the "System setting", "Virtual mode continuation operation
disable warning signal device" of the applicable axis is turned on as warning of
being uncontinuable in virtual mode operation.
It checks for the following cases.
No. Check
Remark
1
Servo amplifier power supply ON for
absolute axis.
• A minor error [901] (power supply on in
real mode)/[9010] (power supply on in
virtual mode) are also set.
2 Anytime during real mode operation.
• It also turns on at the following cases.
1) Home position return
2) Current value change
3) Fixed-pitch feed, speed control ( ), ( )
or speed/position switching control.
Reset the "Virtual mode continuation operation disable warning signal device"
using the Motion SFC program.
Summary of Contents for Q Series
Page 1: ......
Page 19: ...A 18 MEMO ...
Page 129: ...4 90 4 POSITIONING DEDICATED SIGNALS MEMO ...
Page 134: ...5 5 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Page 139: ...5 10 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Page 163: ...6 24 6 DRIVE MODULE MEMO ...
Page 201: ...7 38 7 TRANSMISSION MODULE MEMO ...
Page 257: ...9 12 9 REAL MODE VIRTUAL MODE SWITCHING AND STOP RE START MEMO ...
Page 267: ...10 10 10 AUXILIARY AND APPLIED FUNCTIONS MEMO ...
Page 352: ......