4 - 28
4 POSITIONING DEDICATED SIGNALS
(2) Positioning complete signal (M4001+20n) ................... Status signal
(a) This signal turns on with the completion for the positioning control of the axis
specified with the servo program.
It does not turn on at the start or stop on the way using JOG operation or
speed control.
It does not turn on at the stop on the way during positioning.
It can be used to read an M-code at the positioning completion.
(Refer to Chapter 7 of the "Q173D(S)CPU/Q172D(S)CPU Motion controller
(SV/13/SV22) Programming Manual (REAL MODE)".)
(b) This signal turns off at leading edge of complete signal OFF command
(M4804+20n) or positioning start.
At leading edge of complete signal OFF command (M4804+20n)
Dwell time
OFF
ON
ON
OFF
ON
OFF
V
t
Servo program start
Start accept flag
(M2001 to M2032)
Positioning complete
signal (M4001+20n)
Complete signal OFF
command (M4804+20n)
ON
OFF
At next positioning start
Dwell time
OFF
ON
V
t
ON
OFF
Positioning
completion
Positioning start
Servo program start
Start accept flag
(M2001 to M2032)
Positioning complete
signal (M4001+20n)
ON
OFF
(3) Command in-positioning signal (M4003+20n) ............. Status signal
(a) This signal turns on when the absolute value of the difference between the
command position and the feed current value becomes below the
"command in-position range" set in the parameters of virtual servomotor
(Refer to Section 6.1.2).
This signal turns off in the following cases.
• Positioning control start
• Speed control
• JOG operation
Summary of Contents for Q Series
Page 1: ......
Page 19: ...A 18 MEMO ...
Page 129: ...4 90 4 POSITIONING DEDICATED SIGNALS MEMO ...
Page 134: ...5 5 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Page 139: ...5 10 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Page 163: ...6 24 6 DRIVE MODULE MEMO ...
Page 201: ...7 38 7 TRANSMISSION MODULE MEMO ...
Page 257: ...9 12 9 REAL MODE VIRTUAL MODE SWITCHING AND STOP RE START MEMO ...
Page 267: ...10 10 10 AUXILIARY AND APPLIED FUNCTIONS MEMO ...
Page 352: ......