6. SERVO MOTOR DRIVING
6 - 11
3) Method 7, 8, 11, 12: Homing on home switch and index pulse
These types include the operation at stroke end detection in addition to the operation of Method 3
to Method 6. Thus, the home position is the same as that of Method 3 to Method 6. Method 7 has
the operation of the dog type last Z-phase reference home position return. Method 8 has the
operation of the dog cradle type home position return at a forward rotation start. Method 11 and
12 differ from Method 7 and Method 8 only in the starting direction: the starting direction of
Method 11 and 12 is the reversed direction.
7
7
7
8
8
8
Index Pulse
Home Switch
Positive Limit Switch
4) Method 17 to 30: Homing without index pulse
Method 17 to 30 have the operation of Method 1 to Method 14; however, these types set the
home position not on the Z-phase but on the dog. Method 17 to 30 have the operation of Method
1 to Method 14; however, these types set the home position not on the Z-phase but on the dog.
The following figure shows the operation of the home position return type of Method 19 and
Method 20. Method 19 and Method 20 have the operation of Method 3 and Method 4; however,
these types set the home position not on the Z-phase but on the dog Method 19 has the
operation of the dog type front end reference home position return. Method 20 has the operation
of the dog cradle type home position return; however, the stop position is not on the Z-phase but
on the dog.
19
20
19
Home Switch
20
Summary of Contents for MELSERVO-JE