5. CiA 402 DRIVE PROFILE
5 - 2
5.1 State machine control of the servo amplifier
5.1.1 Function description
The servo amplifier status is managed based on the state machine below. Setting the Controlword (6040h)
from the master station (controller) changes the status of the slave stations (servo amplifiers). The current
servo amplifier status can be read with the Statusword (6041h).
Power on
(14)
(13)
Ready-off/Servo-off
(Main circuit charging
completed)
Ready-off/Servo-off
(During main circuit
charging)
Ready-on/Servo-on
(9)
(8)
(12)
(11)
(16)
(H) Fault
Error occurs
Transition by slave
Transition by master
Transition by slave or master
(10)
(2)
(0)
(1)
(7)
(15)
(3)
(6)
(4)
(5)
(G) Fault reaction active
Servo initialization
in process
In wait for forced stop
reset
Forced stop
deceleration
Occurrence of
alarm
In normal drive
(servo-on)
Alarm handling in process
(forced stop deceleration, alarm
history writing, and alarm display
change)
Drive standby
(servo-off)
In wait for main
circuit charging
(ready-off)
(A) Not ready to switch on
(B) Switch on disabled
(C) Ready to switch on
(D) Switched on
(E) Operation enabled
(F) Quick stop active