Acceleration and deceleration
Parameter
6 - 208
6.11.4
Shortest acceleration/deceleration (automatic acceleration/deceleration)
(Pr. 61 to Pr. 63, Pr. 292, Pr. 293)
The inverter operates in the same conditions as when appropriate values are set in each para-
meter even if acceleration/deceleration time and V/f pattern are not set. This function is useful
when you just want to operate, etc. without fine parameter setting.
When Pr. 570 Multiple rating setting
≠
"2", performing all parameter clear and inverter reset
changes the setting range (refer to section 6.7.5).
Pr.
No.
Name
Initial
Value
Setting Range
Description
Parameters referred to
Refer to
Section
61
Reference cur-
rent
9999
01800
or less
0–500A
Set the reference current during shortest /
optimum acceleration/deceleration.
0
7
8
22
22
Torque boost
Acceleration
time
Deceleration
time
Stall prevention
operation level
Torque limiter
02160
or
more
0–3600A
9999
Rated inverter output current value is refer-
ence
62
Reference value
at acceleration
9999
0–220%
Set the limit value during shortest / optimum
acceleration.
9999
Shortest acceleration: 150% is a limit value
Optimum acceleration: Pr. 61 is reference
63
Reference value
at deceleration
9999
0–220%
Set the limit value during shortest / optimum
deceleration.
9999
Shortest deceleration: 150% is a limit value
Optimum deceleration: Pr. 61 is reference
292
Automatic accel-
eration/decelera-
tion
0
0
Normal mode
1
Shortest acceleration/deceleration (without
brake)
11
Shortest acceleration/deceleration (with
brake)
3
Optimum acceleration/deceleration
5/6
Elevator mode 1, 2 (Refer to section 6.9.3)
7/8
Brake sequence mode 1, 2
(Refer to section 6.13.5.)
293
Acceleration/
deceleration sep-
arate selection
0
0
Both acceleration and deceleration are made
in the shortest acceleration/deceleration
mode
1
Only acceleration is made in the shortest
acceleration/deceleration mode
2
Only deceleration is made in the shortest
acceleration/deceleration mode
Summary of Contents for FR-A700 EC
Page 2: ......
Page 4: ......
Page 24: ...Description of the Case Product Checking and Part Identification 1 4 ...
Page 38: ...Enclosure design Installation 2 14 ...
Page 774: ...Specifications FR A 740 01800 to 12120 Appendix A 4 ...
Page 820: ...Parameter list with instruction codes Appendix A 50 ...
Page 825: ......