Function assignment of external terminals
Parameter
6 - 314
6.14.8
Detection of output torque (TU signal, Pr. 864)
Output the signal when the motor torque rises above the setting value. This function can be
used for electromagnetic brake operation, open signal, etc.
When the output torque reaches or exceeds the detected torque value set in Pr. 864 under real
sensorless vector control, advanced magnetic flux vector control or vector control, the torque
detection signal (TU) turns on.It turns off when the torque falls below the detection torque value.
For the TU signal, set "35 (source logic) or 135 (sink logic)" in Pr. 190 to Pr. 196 (output terminal
function selection) and assign functions to the output terminal.
Pr.
No.
Name
Initial
Value
Setting
Range
Description
Parameters referred to
Refer to
Section
864
Torque detection
150%
0–400%
Set the torque value where the TU signal
turns on.
190–196
Output terminal
function selection
I001597E
Fig. 6-140:
Torque detection
NOTE
When terminal assignment is changed using Pr. 190 to Pr. 196 "Output terminal function
selection", the other functions may be affected. Please make setting after confirming the
function of each terminal.
Sensorless
Sensorless
Sensorless
Magnetic flux
Magnetic flux
Magnetic flux
Vector
Vector
Vector
Output torque [%]
TU
Pr. 864
Time
ON
OFF
Summary of Contents for FR-A700 EC
Page 2: ......
Page 4: ......
Page 24: ...Description of the Case Product Checking and Part Identification 1 4 ...
Page 38: ...Enclosure design Installation 2 14 ...
Page 774: ...Specifications FR A 740 01800 to 12120 Appendix A 4 ...
Page 820: ...Parameter list with instruction codes Appendix A 50 ...
Page 825: ......