Solving Problems
107
Printing Quality
Symptom
Cause
Solution
Vertical
white lines
appear in
image.
The imaging unit,
transfer roller, or fuser
unit are is misinstalled,
old, or damaged.
Confirm the proper installation of the items,
and check them for damage. If necessary,
replace them.
Image is
too light;
there is low
image
density.
The media is moist
from humidity.
Remove the moist media and replace with
new, dry media.
One or more toner
cartridges are
defective.
Remove the toner cartridges and check for
damage. If necessary, replace them.
The imaging unit is old
or damaged.
Remove the imaging unit and check for
damage. If necessary, replace it.
Media type may be set
incorrectly.
Envelopes, glossy stock (set as Thick 2 or
Thick 3), labels, and thick stock have to be
set in the correct mode. See “Media Sizes
and Print Area” on page 19.
The printer is
connected to an outlet
with a voltage or
frequency that does not
match the printer
specifications.
Use a power source with the proper
specifications.
Driver settings are
not correct.
Confirm that you are using the correct driver
settings.
Media is the wrong
size.
Check with your documentation to confirm
the correct media size and type.
Unsupported media is
being used.
Check www.minolta-qms.com/support (click
on Answer Base) for currently approved
media.
Summary of Contents for MAGICOLOR 3300
Page 1: ...magicolor 3300 User s Guide 1800712 001A...
Page 8: ......
Page 9: ...1 Software Installation...
Page 20: ......
Page 21: ...2 Using Media...
Page 52: ......
Page 53: ...3 Color Printing...
Page 59: ...4 Replacing Consumables...
Page 80: ......
Page 81: ...5 Maintaining the Printer...
Page 88: ......
Page 89: ...6 Troubleshooting...
Page 133: ...7 Installing Accessories...
Page 157: ...A Technical Specifications...
Page 186: ......
Page 194: ......