C
Max. load including dead load (load cell, cannot be changed)
The colors have the following meanings:
Red
Weight value is above maximum load (overload) or below -¼d
Green
Weight value is within tolerances
Orange
Weight value is above maximum capacity E
max
(max. capacity of load cell)
[No ID]
The Serial number is hidden.
[Show ID]
The Serial number is visible.
2.
Select the desired load cell and press the [Info] softkey.
Display
Description
Model name
e.g.: PR6204/50tC3
Software version
Software version of the load cell
Load cell serial number
Serial number of the load cell
E
max
Maximum capacity
n
Max. resolution
Y
Minimum LC verification
Z
Minimum preload signal recurrence
Overload
Weight value above max. load
Overload counter
Number of weight values above max. load
The higher the number, the higher the probabi-
lity of a faulty load cell.
The load cell data is displayed:
Transmitter in field housing PR 5230
7 Commissioning
Minebea Intec
EN-214