4.6.6.1
Status indicator
Requirements:
-
The items are defined via
- [Display items]- [Fieldbus LEDs]; see Chapter
.
-
PR 1721/42 is selected via
- [HW-Slots]- [Slot 2].
Display:
1
2
3
4
Constant
grn
:
Cable OK, no reset
mode in the master.
Constant
grn
:
Bus is active.
Constant
red
:
Remote bus is not
active.
Constant
grn
:
PCP communication
is active, hold = 500
ms.
Legend
---
off
red
red
grn
green
4.6.6.2
Connection diagram for a master with three slaves
NOTICE
At terminal "OUT"
, terminal contacts 11 (GND) and 12 (C) must be bridged if
another slave follows.
The terminal is left open when the last slave is connected; see connection diagram.
NOTICE
The cable screens must be guided into the instrument through the cable glands and
connected to terminal "IN"
in terminal contact 6 (S) or "OUT"
in terminal
contact 13 (S); see connection diagram.
Before, during and after installation, make sure that the sealing rings are seated
correctly.
Transmitter in field housing PR 5230
4 Device installation
Minebea Intec
EN-86