Other Useful Functions
1
1
3
Useful Function
5
6
3-49
Perform SAMPLE CUT to Find out the Cause of Cutting Error.
In case that normal data cutting cannot be performed etc., perform
cutting with the sample stored in this plotter to find out the cause of
cutting error.
1
Press the
key in the local mode.
2
Press the jog key
or
to select [SAMPLE
CUT]
.
3
Press the
key.
4
Press the jog key
or
to select the SAMPLE
DATA to be cut.
• There are two types of samples, “Cut” and “Logo.” If you select “Cut,”
proceed to Step 7.
5
Press the
key.
6
Select scale factor using the jog key
or
key to cut Logo.
• Scale factor: 1 to 999%
7
Press the
key for starting cutting.
Result of SAMPLE CUT
Sample data can be cut successfully, but other data cannot.
The host computer is faulty.
Sample data as well as other data cannot be successfully cut either.(When leaving the start/end lines without
cutting off)
Increase the set value of [ADJ-PRS OFS] to raise the pressure for pressing the cutter blade down.
• Execution of SAMPLE CUT will clear the data in the receiver