Technical Information
99
G 1xxx/G 2xxx
3.4
Foreign Object in Drain System
Symptom:
The drain pump or the non-return valve is blocked by a foreign object.
Cause:
Dishes were not, or were inadequately, cleaned.
Remedy:
Install the ring for the microfine filter, mat. no. 5672961 (refer to Figure 050-16).
Figure 050-16:
Microfine Filter Trap
Note:
Once the ring is installed, cleaning the filter has to be done in shorter
intervals.