Technical Information
146
G 1xxx/G 2xxx
Cause:
Heater pressure switch B1/13 defective or blocked by foreign objects.
Remedy:
1. Check the heater pressure switch.
2. Check the connection plug and wiring harness.
3. Replace the heater pressure switch, if necessary. See Section 050-4.20.
Cause:
Circulation pump inoperative. Circulation pressure too low (no pressure at
heater pressure switch). Pump may be blocked by foreign objects.
Remedy:
1. Check the circulation pump for foreign objects by performing the following
steps:
a. Remove the drip pan (Section 010-4.2).
b. Remove the circulation pump (Section 050-4.13).
c. Remove the circulation pump housing cap (Section 050-4.14).
d. Check the inner housing for blockages. Clean as necessary.
2. Check the pump’s hose connections.
3. Check the circulation pump capacitor.
4. Check the circulation pump power supply.
5. Replace the circulation pump, if necessary.
Cause:
Flow meter B3/4 defective (incorrect water quantity registered).
Remedy:
1. Check that the plate with the reed switch on the flow meter is seated correctly.
2. Check that the reed switch connection plug is seated correctly.
3. Replace the reed switch, if necessary (Section 050-4.3).
4. Check the control lead from the electronic to flow meter B3/4.
5. Remove the water diverter and replace if necessary. See Section 050-4.10.
Cause:
Circulation pump winding overheated; winding protection has cut out.
Remedy:
Replace the circulation pump. See Section 050-4.13.
Cause:
After a water intake step, heater pressure switch B1/13 has not opened
switching steps 11–12 and 21–22. This causes the anti-stiction routine to be
started.
Remedy:
Check the heater pressure switch for proper operation by performing the
following steps:
1. Check connection plugs and wiring harness for damage, corrosion or
loose connection.
2. Access service mode (Section 080-4.3) and select the component test menu.
3. Select the first test, wash sequence with heating (R1, Y2, M6).
4. Access the control electronic.
Summary of Contents for ADVANTA G 2170
Page 1: ...TECHNICAL INFORMATION G 1xxx and G 2xxx Dishwashers All US Models 2012 Miele USA ...
Page 43: ...Technical Information 43 G 1xxx G 2xxx 010 Casing ...
Page 47: ...Technical Information 47 G 1xxx G 2xxx Figure 010 5 Side Hinge Retaining Screw ...
Page 48: ...Technical Information 48 G 1xxx G 2xxx 020 Door ...
Page 64: ...Technical Information 64 G 1xxx G 2xxx 030 Front Panel ...
Page 68: ...Technical Information 68 G 1xxx G 2xxx 040 Inner Cabinet ...
Page 77: ...Technical Information 77 G 1xxx G 2xxx 050 Water Paths ...
Page 220: ...Technical Information 220 G 1xxx G 2xxx 100 Fascia Panel Touchtronic Navitronic Incognito ...
Page 226: ...Technical Information 226 G 1xxx G 2xxx 130 Cutlery Tray ...