Technical Information
202
G 1xxx/G 2xxx
Function Programming
Display
Activating/deactivating
the system lock
Select
System lock
. Select
a setting and confirm with
OK
.
This function is deactivated as
standard. This is indicated in the
display by
Off
. If the function is
desired, select
On
.
Setting the temperature
format
Select
Temperature
. Select
a format; confirm with
OK
.
The temperature can be displayed
in
°C
or
°F
as desired.
Activating/deactivating
the buzzer
Select
Buzzer
. Select a
setting and confirm with
OK
.
The options
Off
,
Normal
and
Loud
are shown in the display.
Activating/deactivating
the confirmation tone
Select
Keypad tone
. Select
a setting; confirm with
OK
.
In the standard settings, the
confirmation tone in the form of an
acoustic signal is activated when a
button is operated. The display
indicates this with
On
. To switch off
the confirmation tone, select
Off
.
Brightness adjustment
Select
Brightness
. Select a
setting and confirm with
OK
.
The brightness of the display can
be set in 17 levels, with level 8 as
the standard setting. Brightness
levels are displayed in bar form.
Contrast adjustment
Select
Contrast
. Select a
setting and confirm with
OK
.
The contrast of the display can be
set in 17 levels, with level 8 as the
standard setting. Contrast levels are
displayed in bar form.
Standby
activation/deactivation
Select
Standby
. Select a
setting and confirm with
OK
.
The display shows the options
On
and
Not in current prog.
The display is switched off after
approximately 10 minutes in order
to save energy if, during this period,
no control has been activated.
Activating/deactivating
the memory
Select
Memory
. Select a
setting and confirm with
OK
.
Options:
On
(standard setting),
Off
.
With the memory function, the last
selected program can be saved.
Activating the dealer
demo mode
Select
Dealer
. Select a
setting and confirm with
OK
.
For options, see Section 080-
4.2.13.
Resetting standard
settings
Select
Factory default
. To
reset the parameters
(settings) modified by the
customer to their standard
settings, confirm with
OK
.
The display reads
Reset
.
Adjusting the main wash
temperature
Select
Temperatures
, then
Main wash
. Select a setting
and confirm with
OK
.
Options:
Normal
and
Increased
.
Increased wash temperature results
in a longer running time.
Water quantity
normal/increased
Select
Water plus
. Select a
setting and confirm with
OK
.
Options:
Standard
and
Increased
. If
Increased
is selected, water intake
increases by 16.9 fl.oz. (500mL).
Activating/deactivating
sensor softener, manually
setting water hardness
1
Select
Water hardness
.
Select a setting and confirm
with
OK
.
Auto
= Sensor softener activated.
The water hardness at the
installation site can also be
manually set. Water hardness
range: 1°d to 70°d. See Section
080-4.2.14.
Summary of Contents for ADVANTA G 2170
Page 1: ...TECHNICAL INFORMATION G 1xxx and G 2xxx Dishwashers All US Models 2012 Miele USA ...
Page 43: ...Technical Information 43 G 1xxx G 2xxx 010 Casing ...
Page 47: ...Technical Information 47 G 1xxx G 2xxx Figure 010 5 Side Hinge Retaining Screw ...
Page 48: ...Technical Information 48 G 1xxx G 2xxx 020 Door ...
Page 64: ...Technical Information 64 G 1xxx G 2xxx 030 Front Panel ...
Page 68: ...Technical Information 68 G 1xxx G 2xxx 040 Inner Cabinet ...
Page 77: ...Technical Information 77 G 1xxx G 2xxx 050 Water Paths ...
Page 220: ...Technical Information 220 G 1xxx G 2xxx 100 Fascia Panel Touchtronic Navitronic Incognito ...
Page 226: ...Technical Information 226 G 1xxx G 2xxx 130 Cutlery Tray ...