2. Pump housing cap removal (Section 050-4.14).
3.
Slide shutter removal (Section 050-4.15).
4. Remove the drive retaining screws (Figure 050-23, Item 1).
Figure 050-23:
Drive Cam
Warning!
When re-installing, check that the O-ring is seated correctly on the drive cam.
Before re-installing the slide shutter in the pump housing, make sure that the
double tooth on the drive cog wheel points to the arrow on the housing.
4.17
Pump Impeller Removal
1. Remove the circulation pump; see Section 050-4.13.
2. Pump housing cap removal (Section 050-4.14).
3. Hold the shaft base with suitable pliers and unscrew the pump impeller
clockwise to remove.
4.18
Pump Housing Removal
1. Remove the circulation pump; see Section 050-4.13.
2. Pump housing cap removal (Section 050-4.14).
3. Pump impeller removal (Section 050-4.17).
4. Remove the screws securing the pump housing.
5. Turn the pump housing counterclockwise to its stop.
6. Lift the pump housing from its guide.
Summary of Contents for ADVANTA G 2170
Page 1: ...TECHNICAL INFORMATION G 1xxx and G 2xxx Dishwashers All US Models 2012 Miele USA ...
Page 43: ...Technical Information 43 G 1xxx G 2xxx 010 Casing ...
Page 47: ...Technical Information 47 G 1xxx G 2xxx Figure 010 5 Side Hinge Retaining Screw ...
Page 48: ...Technical Information 48 G 1xxx G 2xxx 020 Door ...
Page 64: ...Technical Information 64 G 1xxx G 2xxx 030 Front Panel ...
Page 68: ...Technical Information 68 G 1xxx G 2xxx 040 Inner Cabinet ...
Page 77: ...Technical Information 77 G 1xxx G 2xxx 050 Water Paths ...
Page 220: ...Technical Information 220 G 1xxx G 2xxx 100 Fascia Panel Touchtronic Navitronic Incognito ...
Page 226: ...Technical Information 226 G 1xxx G 2xxx 130 Cutlery Tray ...