Technical Information
96
G 1xxx/G 2xxx
The maximum spray arm speed is approximately 50 revolutions per minute.
Therefore, the next pulse can be registered at the earliest approximately
1.2 seconds after the start of the monitoring time.
If a fault is indicated, the indication will remain active even after the door has
been opened. To cancel the fault indication, the door must be closed again.
Figure 050-14:
Middle and Bottom Spray Arm Sensors
1
Spray arm sensor, middle spray arm
2
Spray arm sensor, bottom spray arm
2.18 Filter
Combination
with Microfine Filter
Circulation pump M6 pumps the wash water from the sump via the filter
combination to the spray arms. The circulating wash water is filtered via 2
parallel paths. A proportion of the water flows through the central opening of
the coarse filter and then passes through the conical microfine filter (Figure
050-15, Item 3). The remainder passes directly through the large surface
area fine filter (Figure 050-15, Item 2), which contains a small hole for
ventilation of the suction area of the circulation pump. Both partial currents
are continually redistributed via constant circulation in the cabinet, so that all
Summary of Contents for ADVANTA G 2170
Page 1: ...TECHNICAL INFORMATION G 1xxx and G 2xxx Dishwashers All US Models 2012 Miele USA ...
Page 43: ...Technical Information 43 G 1xxx G 2xxx 010 Casing ...
Page 47: ...Technical Information 47 G 1xxx G 2xxx Figure 010 5 Side Hinge Retaining Screw ...
Page 48: ...Technical Information 48 G 1xxx G 2xxx 020 Door ...
Page 64: ...Technical Information 64 G 1xxx G 2xxx 030 Front Panel ...
Page 68: ...Technical Information 68 G 1xxx G 2xxx 040 Inner Cabinet ...
Page 77: ...Technical Information 77 G 1xxx G 2xxx 050 Water Paths ...
Page 220: ...Technical Information 220 G 1xxx G 2xxx 100 Fascia Panel Touchtronic Navitronic Incognito ...
Page 226: ...Technical Information 226 G 1xxx G 2xxx 130 Cutlery Tray ...