Technical Information
174
G 1xxx/G 2xxx
Options:
Function Programming
Display
Software version ID check
Do not press the
Tab
button. The "Tab" LED is
not lit.
The display shows the software
version ID no. in consecutive digits
(e.g., -
1304
).
Reset
Press the
Tab
button 1x.
The "Tab" LED flashes 1x
rapidly intermittently.
Press the
Program
button
to reset all standard
settings.
This programmable function can be
used to reset all modifiable
parameters to their standard
settings. The display shows
p
and a
digit alternately:
p0
= Non-standard
settings have been made;
p1
= All
settings reset to standard settings
or no modifications have been
made.
Water hardness setting
1
Press the
Tab
button 2x.
The "Tab" LED flashes 2x
rapidly intermittently.
Press the
Program
button
as appropriate to set the
desired water hardness.
The display shows
p
and the digit/s
of the set value alternately.
Setting range:
p1
to
p70
; see Table
080-12.
2
Dispensed rinse aid
quantity setting
Press the
Tab
button 3x.
The "Tab" LED flashes 3x
rapidly intermittently.
Press the
Program
button
as appropriate to make the
desired setting.
The display shows
P
and a digit
alternately: e.g.,
P3
(standard
setting) indicates a dispensed
quantity of 0.1 fl.oz. (3mL). Setting
range: 0 - 0.2 fl.oz. (0 - 6 mL). See
Table 080-13.
Buzzer on/off
Press the
Tab
button 4x.
The "Tab" LED flashes 4x
rapidly intermittently.
Press the
Program
button
as appropriate to make the
desired setting.
The display shows
p
and a digit
alternately:
p0
= Buzzer off;
p1
=
Buzzer on.
Adjust
Sensor Wash
program
Press
Tab
5x. The "Tab"
LED flashes 5x rapidly
intermittently. Press the
Program
button to change
the setting.
The display shows
P
and a digit
alternately. Setting options:
P0
=
Standard program cycle (factory
setting);
P1
= Adjusted program
cycle. The
Sensor Wash
program
can be adjusted in this parameter to
deal with stubborn soiling (or
otherwise low overall soiling). If this
option is selected, the main wash
temperature is increased to 131°F
and, as a result, the program
duration is extended.
Resetting standard
settings
Press
Tab
12x. The "Tab"
LED flashes 1x slowly and
2x rapidly intermittently.
Press the
Program
button
to reset all settings back to
their factory values.
This programmable function can be
used to reset all customer-modified
parameters back to their standard
settings. The display shows
P
and a
digit alternately.
P0
= Settings have
been modified;
P1
= All settings reset
to standard settings or no
modifications have been made.
Summary of Contents for ADVANTA G 2170
Page 1: ...TECHNICAL INFORMATION G 1xxx and G 2xxx Dishwashers All US Models 2012 Miele USA ...
Page 43: ...Technical Information 43 G 1xxx G 2xxx 010 Casing ...
Page 47: ...Technical Information 47 G 1xxx G 2xxx Figure 010 5 Side Hinge Retaining Screw ...
Page 48: ...Technical Information 48 G 1xxx G 2xxx 020 Door ...
Page 64: ...Technical Information 64 G 1xxx G 2xxx 030 Front Panel ...
Page 68: ...Technical Information 68 G 1xxx G 2xxx 040 Inner Cabinet ...
Page 77: ...Technical Information 77 G 1xxx G 2xxx 050 Water Paths ...
Page 220: ...Technical Information 220 G 1xxx G 2xxx 100 Fascia Panel Touchtronic Navitronic Incognito ...
Page 226: ...Technical Information 226 G 1xxx G 2xxx 130 Cutlery Tray ...