Technical Information
154
G 1xxx/G 2xxx
3.29
Fault Code F51: Heater Pressure Switch
Symptom:
The program is interrupted and the drain pump is operated.
See Table 080-3 for model-specific fault indications.
Background information:
Start position:
Figure 080-12:
Circuit Test Path for
F51
(Initial State)
One second after program start, heater relay K1/1 is activated. This enables
a check as to whether the contacts on heater pressure switch B1/13 have
closed on switching steps 21/22 or 11/12. See Figure 080-13. If the electronic
receives no power, an
F51
fault is stored.
Figure 080-13:
Circuit Test Path for
F51
(Testing State)
Cause:
Heater relay defective; contact open.
Remedy:
Replace the heater relay.