Technical Information
114
G 1xxx/G 2xxx
4.28
Filter Combination Assembly (New Microfine Filter and Handle)
Note:
During assembly, the dishwasher is used as a guide.
If a new microfine filter and handle (crown coarse filter) are used, a locking
piece is not required.
1. Place the microfine filter in the sump. Ensure that the lug is positioned
towards the rear of the machine.
2. Turn the microfine filter clockwise as far as possible; see Figure 050-26.
3. Install the large surface area fine filter.
Figure 050-26:
Microfine Filter Installation
4. Press the large surface area fine filter downwards; see Figure 050-27, Item 1.
5. Install the handle (crown coarse filter) and turn it clockwise as far as possible;
see Figure 050-27, Item 2.
6. Carry out a visual check: The handle (crown coarse filter) should be parallel
to the door as shown in Figure 050-27.
7. Carry out a functional check: Remove the filter combination and re-install it.
Summary of Contents for ADVANTA G 2170
Page 1: ...TECHNICAL INFORMATION G 1xxx and G 2xxx Dishwashers All US Models 2012 Miele USA ...
Page 43: ...Technical Information 43 G 1xxx G 2xxx 010 Casing ...
Page 47: ...Technical Information 47 G 1xxx G 2xxx Figure 010 5 Side Hinge Retaining Screw ...
Page 48: ...Technical Information 48 G 1xxx G 2xxx 020 Door ...
Page 64: ...Technical Information 64 G 1xxx G 2xxx 030 Front Panel ...
Page 68: ...Technical Information 68 G 1xxx G 2xxx 040 Inner Cabinet ...
Page 77: ...Technical Information 77 G 1xxx G 2xxx 050 Water Paths ...
Page 220: ...Technical Information 220 G 1xxx G 2xxx 100 Fascia Panel Touchtronic Navitronic Incognito ...
Page 226: ...Technical Information 226 G 1xxx G 2xxx 130 Cutlery Tray ...