Technical Information
89
G 1xxx/G 2xxx
By monitoring the speed in this way and thus controlling additional water
intake precisely can reduce energy and water consumption. The potential
savings are approximately 15 percent water and 19 percent energy.
Note:
This system has an additional advantage. Good wash results are also
ensured if the dishwasher load includes items with less than ideal shape
(e.g., deep cups) as the controlled additional water intake will replace the
water that may be trapped in such pieces. This similarly applies if, e.g., a
light plastic bowl should be turned over and filled inadvertently by the
stream of water.
2.11
MPPW Circulation Pump (with Frequency Converter & Slide Shutter)
Circulation pump MPPW is fitted with a frequency converter and a slide shutter.
Figure 050-9:
MPPW Circulation Pump
For connection plug voltages, see Figure 050-10.
1
Heater pressure switch, B1/13
2
Slide shutter position, B3/12, and motor, M24
3
Pump housing, frequency converter electronic
4
Middle spray arm inlet
5
Top spray arm inlet
6
Heater, R1
7
Retaining lugs for pump housing cap
8
Retaining screws for pump housing cap
9
Bottom spray arm inlet
Summary of Contents for ADVANTA G 2170
Page 1: ...TECHNICAL INFORMATION G 1xxx and G 2xxx Dishwashers All US Models 2012 Miele USA ...
Page 43: ...Technical Information 43 G 1xxx G 2xxx 010 Casing ...
Page 47: ...Technical Information 47 G 1xxx G 2xxx Figure 010 5 Side Hinge Retaining Screw ...
Page 48: ...Technical Information 48 G 1xxx G 2xxx 020 Door ...
Page 64: ...Technical Information 64 G 1xxx G 2xxx 030 Front Panel ...
Page 68: ...Technical Information 68 G 1xxx G 2xxx 040 Inner Cabinet ...
Page 77: ...Technical Information 77 G 1xxx G 2xxx 050 Water Paths ...
Page 220: ...Technical Information 220 G 1xxx G 2xxx 100 Fascia Panel Touchtronic Navitronic Incognito ...
Page 226: ...Technical Information 226 G 1xxx G 2xxx 130 Cutlery Tray ...