Technical Information
71
G 1xxx/G 2xxx
sheeting, which serve as condensation surfaces. The second impeller
transports the water vapor in the appliance to the condensation surfaces.
In Version 2, a split-pole motor (approximately 19 watts) drives one impeller,
which transports cool air to the outer surface of the right side panel.
3 Fault
Repair
3.1
Condensation Forms on Adjacent Cabinets
Symptom:
During the drying cycle, condensation may form on the cabinets to the left
and right of the dishwasher.
Cause:
Extraneous air is sucked in the area of the condenser.
Remedy:
1. Remove the right side panel (Section 010-4.1).
2. Seal the opening behind the rib of the condenser with silicone sealer
(such as Thermostat); see Figure 040-2.
Figure 040-2:
Condenser Pocket
Note:
In dishwashers starting with production number 33/65009505, the opening
at the condenser pocket is already closed.
Remedy:
Modify the dishwasher with the “Vapors VI” conversion kit.
Summary of Contents for ADVANTA G 2170
Page 1: ...TECHNICAL INFORMATION G 1xxx and G 2xxx Dishwashers All US Models 2012 Miele USA ...
Page 43: ...Technical Information 43 G 1xxx G 2xxx 010 Casing ...
Page 47: ...Technical Information 47 G 1xxx G 2xxx Figure 010 5 Side Hinge Retaining Screw ...
Page 48: ...Technical Information 48 G 1xxx G 2xxx 020 Door ...
Page 64: ...Technical Information 64 G 1xxx G 2xxx 030 Front Panel ...
Page 68: ...Technical Information 68 G 1xxx G 2xxx 040 Inner Cabinet ...
Page 77: ...Technical Information 77 G 1xxx G 2xxx 050 Water Paths ...
Page 220: ...Technical Information 220 G 1xxx G 2xxx 100 Fascia Panel Touchtronic Navitronic Incognito ...
Page 226: ...Technical Information 226 G 1xxx G 2xxx 130 Cutlery Tray ...