Technical Information
111
G 1xxx/G 2xxx
Figure 050-24:
Removing the Drain Pump
Note:
When installing, apply a little water or soap solution to the pump seal as a
lubricant. After installation, check all the pump fastening points.
4.23
Removing the Sump
1. Remove as much residual water as possible from the sump and drain hose.
2. Open the door.
3. Remove the bottom basket.
4. Remove the bottom spray arm.
5. Unscrew the bottom spray arm flange.
6. Remove the filter combination.
7. Lay the dishwasher onto its back.
8. Remove the drip pan. See Section 010-4.2.
9. Remove the float switch.
10. Disconnect the hoses.
11. Disconnect the NTC sensor connections.
12. Remove the drain pump. See Section 050-4.22.
13. Remove the circulation pump. See Section 050-4.13.
14. Remove the heater wiring harness from the cable guide.
15. Unscrew the hose clip and remove it from the sealing ring.
16. Remove the sump by pulling down firmly and evenly on the drain pump or
circulation pump connections.
17. Remove the sealing ring.
Summary of Contents for ADVANTA G 2170
Page 1: ...TECHNICAL INFORMATION G 1xxx and G 2xxx Dishwashers All US Models 2012 Miele USA ...
Page 43: ...Technical Information 43 G 1xxx G 2xxx 010 Casing ...
Page 47: ...Technical Information 47 G 1xxx G 2xxx Figure 010 5 Side Hinge Retaining Screw ...
Page 48: ...Technical Information 48 G 1xxx G 2xxx 020 Door ...
Page 64: ...Technical Information 64 G 1xxx G 2xxx 030 Front Panel ...
Page 68: ...Technical Information 68 G 1xxx G 2xxx 040 Inner Cabinet ...
Page 77: ...Technical Information 77 G 1xxx G 2xxx 050 Water Paths ...
Page 220: ...Technical Information 220 G 1xxx G 2xxx 100 Fascia Panel Touchtronic Navitronic Incognito ...
Page 226: ...Technical Information 226 G 1xxx G 2xxx 130 Cutlery Tray ...