Technical Information
62
G 1xxx/G 2xxx
Note:
During reassembly, ensure that:
1. The protective foil is NOT pushed to one side or torn.
2. The foil tongue is positioned between the retaining bracket and door lock.
3. The foil is positioned under the plug area when the retaining bracket is re-
installed.
Important:
Ensure that the sealing ring under the door lock retaining screw is re-
installed during reassembly.
4.6
Door Switch Replacement (Touchtronic/Novotronic/Navitronic)
1. Remove the door lock (Section 020-4.5).
2. Bend the retaining lug on the switch to the side.
3. Replace the switch.
4.7
Door Lock with Contact Switch Removal (Incognito)
1. Remove the door outer panel (Section 030-4.3).
2. Remove the fascia panel (Section 100-4.2).
3. Remove the screws from the sides of the door inner panel.
4. Remove the lock retaining screw.
5. Remove the holder with electronic.
6. Remove the lock with door contact switch.
7. Disconnect the door contact switch plug connections.
4.8
Activating the Door Lock Emergency Release (Incognito)
1. Remove the door outer panel (Section 030-4.3).
2.
To return the locking latch to the right position, push on the emergency
release with a screwdriver; see Figure 020-15, Item 1
.
Figure 020-15:
Door Lock Emergency Release
Summary of Contents for ADVANTA G 2170
Page 1: ...TECHNICAL INFORMATION G 1xxx and G 2xxx Dishwashers All US Models 2012 Miele USA ...
Page 43: ...Technical Information 43 G 1xxx G 2xxx 010 Casing ...
Page 47: ...Technical Information 47 G 1xxx G 2xxx Figure 010 5 Side Hinge Retaining Screw ...
Page 48: ...Technical Information 48 G 1xxx G 2xxx 020 Door ...
Page 64: ...Technical Information 64 G 1xxx G 2xxx 030 Front Panel ...
Page 68: ...Technical Information 68 G 1xxx G 2xxx 040 Inner Cabinet ...
Page 77: ...Technical Information 77 G 1xxx G 2xxx 050 Water Paths ...
Page 220: ...Technical Information 220 G 1xxx G 2xxx 100 Fascia Panel Touchtronic Navitronic Incognito ...
Page 226: ...Technical Information 226 G 1xxx G 2xxx 130 Cutlery Tray ...