4.4.2.8.1 Device Details
SFP modules include an EEPROM to identify the module capabilities and these
may be read using the SFP device details option. The information display is as
shown below:
Metrodata FCM9002 "" Alarms: Major
SFP Info
--------
Transmit
Status Type Vendor Part No. Wavelength
----------------------------------------------------------------------
Good 1000BASE-SX HG GENUINE MXPD-248S-F 850nm
SFP Diagnostic Info
-------------------
Diagnostic Current Alarm Threshold Warning Threshold
Item Status Value Unit High Low High Low
----------------------------------------------------------------------
Tx Power OK 8 dBm 8 8 8 8
Rx Power alarm -26 dBm 0 -17 -1 -15
Bias OK 4.2 mA 20.0 1.0 15.0 1.0
Temp OK 44 C 85 -5 80 0
Supply OK 3.28 V 3.60 3.0 3.50 3.10
<Esc> - exit, <Enter> - refresh
4.4.2.8.2 Notifications
The SFP notifications menu configures the actions for alarm and trap generation
when the disagnostic values exceed the alarm or warning threshold values.
Metrodata FCM9002 "FCM9002_Fibre" Alarms: none
NOTIFICATIONS
1 - Temp High Alarm & Warning
2 - Temp Low None
3 - Supply High None
4 - Supply Low None
5 - Bias High None
6 - Bias Low None
7 - Tx Power High None
8 - Tx Power Low None
9 - Rx Power High None
A - Rx Power Low Alarm & Warning
B - SFP Removed None
C - OTDR Fault None
First CAPITAL - select item
<escape> - exit menu