4.7.2.4.2 View Results
While a test is running, the view results screen shows the current status. An
example is shown below:
Metrodata FCM9002 "FCM9002" Alarms: Major
Test Report
-----------
unit node name: "FCM9002"
unit mac address: 00:c0:81:00:13:ad
start time: 10:52:02 Tue 27/11/2012
test regime: Y.1564
---
testing Flow1 "Port1 Service 100M"
go/nogo test
%cir: 10..
test results:
tx frames 25
rx good frames 24
frame loss (%) 4.000002
max delay (us) 11.0
max delay variation (us) 0.0
go/nogo test failed
---
testing complete
<Escape> - exit, other key – refresh
The results report grows as the testing progresses, and may be refreshed whilst
the test is running to show the latest progress. The report lists the outcomes of
each test performed and gives a pass/fail indication.
Once the test is complete, indicated by the “Testing Complete” message in the
report, it may be saved using TFTP as proof of the services meeting the SLA
when the services are initially provisioned.