4.7.2.5 Manual Mode Testing
Whilst Y.1564 testing allows for semi automated validation of the SLA defined
per flow, it may be desirable to perform a more detailed or tightly controlled test
to diagnose a network, or service problem and this is the purpose of the Manual
Mode tester.
The manual mode test setup menu is shown below:
Metrodata FCM9002 "FCM9002" Alarms: Major
SAM
Regime Manual Control
Mode Tester
test Duration 00:01:00
Test State Stopped
maNual Setup <menu>
tEst Summary <display>
Clear Results
First CAPITAL - select item
<escape> - exit menu
4.7.2.5.1 Test Duration
The manual tester will run for the configured time. The time is entered in the
format:
Hours : Minutes : Seconds
Note, the duration must include all three parameters, such that a 30 second test
is configured as 0:0:30
4.7.2.5.2 Test State
When the test traffic is configured, clear the results and then change the state to
Running. The test will then run for the defined test period.
Stopped
Test Not Running
Running
Test Running