4.7.2.5.3 Manual Setup
The Manual Setup Menu configures the tester parameters. The menu is shown
below:
Metrodata FCM9002 "FCM9002_Left" Alarms: Major
MANUAL SETUP
Flow 1
s-VLAN None
c-vLAN 128
Local MAC 00:c0:81:00:13:ad
Remote MAC 00:c0:81:ff:00:00
Packet size 68
pAcket rate 17462
Bandwidth 94.999% of CIR
bUrst Size 1 packet(s)
burst siZe 0.680% of CBS
First CAPITAL - select item
<escape> - exit menu
4.7.2.5.3.1 Flow
In order for a test to be performed, at least one flow must have been configured.
When the flow number is entered, the S/C-Tag information is retrieved and used
for the test traffic stream.
4.7.2.5.3.2 S-VLAN / C-VLAN
This menu item shows the Tag structure for the test packets.
By default, the C-VLAN will assume the ID of the Control VLAN as defined in the
flow configuration. This may be changed to use any other ID that is part of the
flow definition.
4.7.2.5.3.3 Local MAC
This is the MAC address of this unit. It is a fixed value, and is used as the
Source Address for all test packets.