FCM9002 USER MANUAL
76-02-095 Rev.B
Page 95 of 145
Each diagnostic value may be configured for either:
None
No Action
Alarm
Generate an Alarm/Trap when the alarm
threshold is exceeded.
Alarm & Warning
Generate an Alarm/Trap when either the Alarm
or Warning thresholds are exceeded.
4.4.2.8.3 OTDR SFP module Support
The FCM9002 supports the OpticalZonu SFP modules which have an integrated
OTDR measurement facility. When the OTDR SFP modules are used both fibre
length while operational, and distance to fault measurements are provided.
When an OTDR SFP module is in use the SFP Device Details menu displays
additional information when in a fault condition as shown below:
Metrodata FCM9002 "FCM9002_Copper" Alarms: Major
SFP Info Interface: SFP
--------
Transmit
Status Type Vendor Part No. Wavelength
-----------------------------------------------------------------------
Good 1000BASE-LX OpticalZonu,Corp AF6-151G1-SU 1510nm
Diagnostic Current Alarm Threshold Warning Threshold
Item Status Value Unit High Low High Low
----------------------------------------------------------------
Tx Power OK 0 dBm 3 -7 2 -5
Rx Power OK 0 dBm 3 -25 2 -19
Bias OK 57 mA 70 2 60 4
Temp OK 59 C 85 -45 75 -35
Supply OK 3.19 V 3.63 2.97 3.49 3.10
Fault Fault Fibre Last Fault Last Fault Last Fault
Status Distance Length Start Clear Distance
-----------------------------------------------------------------------
No Fault 458m 875m 16/7/2013 09:33:57
<Esc> - exit, <Enter> - refresh
And when the fault is cleared, the display changes as below:
Metrodata FCM9002 "FCM9002_Copper" Alarms: Major